What Windowless Skyscraper Floors Do and Why They Need Louvers

The Empire State Building has 15 mechanical levels among its 102 floors. These floors hold equipment that moves air, water, electricity and heat through the tower.

From the street, a mechanical level often looks like a dark band of horizontal slats behind a glass facade. Those slats are louvers. They allow air to enter and leave the building, help keep rain away from machinery and explain why these floors have no ordinary windows.

The service levels inside a tower

A mechanical floor is a complete story given over to building equipment. The systems are often grouped under MEP, meaning mechanical, electrical and plumbing. They need space for operation, inspection and replacement, and their pipes, ducts and cables continue vertically through the tower.

The equipment supports occupied floors above and below. A typical mechanical level can contain air handling units, pumps, electrical systems, water tanks, elevator machinery and service risers. A common rule of thumb places one mechanical floor for every 10 tenant floors, or about 10% of the building. The actual proportion depends on the design.

The Empire State Building uses a larger share than that rule of thumb. Its 15 mechanical floors, 87 through 101, make up 14% of the building. Employees can reach them through an internal stair.

The Burj Khalifa uses a different arrangement. Its mechanical floors appear at intervals of about 30 storeys. Electrical substations, water tanks, pumps and air handling units are distributed through the tower so equipment remains closer to the zones it serves.

Air, cooling and water systems

Air conditioning chiller systems and refrigerant flow systems cool the occupied spaces. Central equipment sends air through vertical ducts, and horizontal ducts spread it across each floor. Air handling units are placed to keep those duct runs shorter, which reduces energy loss. Variable air volume systems change airflow and temperature for the needs of each floor or zone.

Mechanical levels also contain riser shafts. These shafts carry utilities and services through the building. Water and drainage pipes connect the floors, while high-rise electrical distribution commonly uses modular cable bus or busway systems.

Service cores bring several functions together. They can contain elevator shafts, electrical and telecommunications rooms, and mechanical rooms. Some mechanical levels include elevator machine rooms with drive units, motors, pumps, valves, controllers, governors and other electrical components.

Elevator machine rooms are typically kept between 60°F and 80°F, with relative humidity between 35% and 60%.

The Empire State Building still receives steam from Con Edison's district steam network. Steam is produced at six sites and travels through more than 100 miles of pipe around lower Manhattan before the building's plant uses it for heat and cooling. The building was completed in the 1930s.

Why the facade uses slats instead of glass

Mechanical equipment needs outside air. It also produces heat that must be rejected outside the tower. A glass wall would block the airflow needed by the equipment and limit the escape of heat, so mechanical floors usually have external vents or louvers across much of their perimeter.

The louvers are angled metal slats. They allow air to enter and exhaust air from the equipment areas while offering some protection from rain. On a glass tower, the result is easy to spot: a dark, open-looking band interrupts the otherwise continuous facade.

Tenant floors in modern skyscrapers generally do not have windows that occupants can open. Mechanical ventilation operates throughout the building, and the floor dedicated to moving air may therefore be the one level whose outer wall visibly opens to the air.

Who can enter these hidden floors?

Mechanical floors are usually reached through service routes, most often a restricted stairwell. In office towers, access doors may require an access card, and elevator controls may prevent passengers from selecting certain floors. These systems depend on locks and readers being installed and maintained at each level.

Other concealed levels have different jobs. Areas of refuge are fire-rated spaces where people who cannot use stairs can wait for assistance. Section 1009 of the International Building Code addresses these areas and requires two-way communication.

The Burj Khalifa has pressurized, air-conditioned refuge floors every 13 floors. They include floors G, 13, 26, 39 and 52. These spaces support phased evacuation, in which sections of a very tall building are cleared in stages.

Sky lobbies and structural levels

A sky lobby is another service-related level. Express elevators stop there, and passengers transfer to local elevator banks. The original World Trade Center had transfer floors on the 44th and 78th floors. This system reduced the shaft space required for elevators that would otherwise run from the ground to every level.

A soft story concerns stiffness, with one classification using less than 70% of the stiffness of the floor above or less than 80% of the average stiffness of the three floors above. A weak story concerns strength. Soft stories commonly occur in open ground floors used for parking or shops, not in mechanical floors.

Structural transfer levels can also take up otherwise usable floor space. Outrigger systems connect the central core to columns around the perimeter, while belt trusses carry lateral forces back toward the core. Their large structural members can leave too little usable space for offices, so the level is usually combined with a mechanical floor behind the same slatted facade.

The visible sign of a mechanical floor

The louvered perimeter lets outside air reach mechanical equipment and allows heat to leave while helping keep rain away from machinery. From the street, it appears as a dark band of horizontal slats inside an otherwise continuous glass facade.


Watch the full video: Why Every Skyscraper Has a Floor With NO Windows (And What's Inside)

Read the full article: Why Every Skyscraper Has a Floor With NO Windows (And What's Inside)

More stories from Nutt Curious: https://parallel16.stream/nuttcurious/

Follow Nutt Curious:
YouTube · Pinterest · Tumblr · Flipboard

Nhận xét

Bài đăng phổ biến từ blog này

Cruise Ship Crew Life: Cabins, Meals, Shifts and Months at Sea

Inside a Tunnel Boring Machine: 20 Workers, Pressure and Repairs

Inside a 44-Hour B-2 Mission: How Two Pilots Slept, Ate and Refueled